Product Overview

The Opti Logic OL4054 is a 4-slot RTU that serves as a critical component in industrial automation systems, providing point-of-use I/O and operator panel capabilities with a high-speed link to a PC. It features a compact size with dimensions of 5.0″x 3.0″x 3.0″ and weighs approximately 0.2 kilograms. Typically powered by a DC power supply with a working voltage range of 8-30VDC, it offers flexible slot design, supporting the insertion of different I/O modules based on actual needs to achieve various functions such as switch input/output and analog input/output. The Opti Logic driver can automatically detect the position of each module in the RTU. Some modules require slot 0, while others have more flexible placement. It also supports communication via Ethernet, enabling data exchange with OPC clients using the UDP protocol and potentially other communication protocols to adapt to different industrial control systems. Additionally, it may offer serial communication functionality for connecting to other devices or local configuration. The device’s node ID in the network can be set via an address switch, ranging from 0 to 99, and each device must have a unique IP address to ensure its uniqueness in the Ethernet network. Due to its remote monitoring and control capabilities, it is widely applicable in industrial automation, power dispatching, municipal management, and oil and gas fields. It can be used to monitor and control sensors, actuators, and other equipment at remote sites, achieving functions such as data collection, equipment control, and status monitoring.

Technical Specifications

Parameter Value
Product Model Opti Logic OL4054
Manufacturer OPTIMATION, Inc.
Product Type 4-Slot RTU
Dimensions (W×H×D) 5.0″x 3.0″x 3.0″
Weight Approx. 0.2 kg
Power Supply DC power supply, 8-30VDC
Number of Slots 4
Communication Protocol Ethernet (UDP protocol), may support other protocols
Address Setting Node ID 0-99, unique IP address
Operating Temperature -10°C to +55°C
Storage Temperature -25°C to +70°C
Relative Humidity 5% to 95% (non-condensing)
Protection Rating IP54
Mounting Method DIN rail or panel mounting

Key Features and Benefits

  • Flexible Slot Design: The Opti Logic OL4054 features 4 slots, allowing users to insert different I/O modules as needed to achieve diverse functionalities such as switch input/output and analog input/output. This modular design enhances flexibility and adaptability, enabling users to customize configurations based on specific application requirements.
  • Powerful Communication Capabilities: It supports Ethernet communication, enabling data exchange with OPC clients using the UDP protocol. It may also support other communication protocols to ensure compatibility with various industrial control systems. Additionally, it may offer serial communication functionality for connecting to other devices or for local configuration, meeting the communication needs of different industrial scenarios.
  • Convenient Address Setting: The device’s node ID in the network can be set via an address switch, ranging from 0 to 99. Each device must have a unique IP address to ensure its uniqueness in the Ethernet network, simplifying network configuration and management.
  • Wide Application Range: Due to its remote monitoring and control functions, the Opti Logic OL4054 is suitable for industrial automation, power dispatching, municipal management, oil and gas fields, and other industries. It can monitor and control sensors, actuators, and other equipment at remote sites, achieving data collection, equipment control, and status monitoring. It helps improve the efficiency and reliability of industrial processes and reduces operational costs.
  • Compact and Durable Design: With compact dimensions and lightweight construction, the Opti Logic OL4054 is easy to install and deploy. It features a protection rating of IP54, enabling stable operation in harsh industrial environments.

Application Scenarios

  • Industrial Automation: In manufacturing plants, the Opti Logic OL4054 can be used to monitor and control the operation of production line equipment, such as sensors, actuators, and controllers. It collects real-time data from production equipment and transmits it to the control center for centralized monitoring and management. It also enables remote control of equipment, optimizing production processes and improving production efficiency and quality.
  • Power Dispatching: In power systems, it can be deployed at substations and power plants to monitor equipment parameters such as voltage, current, and power. It transmits data to the dispatching center to assist dispatchers in making informed decisions. It also supports remote control of switchgear and other equipment, enabling automated power dispatching and ensuring reliable power supply.
  • Municipal Management: In municipal infrastructure such as water supply and drainage systems, gas supply systems, and traffic control systems, the Opti Logic OL4054 can monitor and control the operation of related equipment. For example, it can monitor water levels in water supply and drainage systems, control pump operations, and manage traffic signals to enhance the operational efficiency and service quality of municipal facilities.
  • Oil and Gas Fields: In oil and gas production sites, it can monitor parameters such as pressure, temperature, and flow rate of oil and gas pipelines and wells. It transmits data to the monitoring center for real-time monitoring and analysis. It also enables remote control of valves and pumps, ensuring safe and efficient oil and gas production.

Related Models

  • Opti Logic OL4058: An 8-slot RTU that supports more I/O modules and offers higher I/O capacity than the Opti Logic OL4054, suitable for large-scale industrial automation projects with higher I/O requirements.
  • Opti Logic OL2602: A dual RS232 module used for serial communication. Up to two OL2602 modules can be used with the Opti Logic OL4054, placed in slots 0 and 1, enabling connection to serial devices for expanded communication capabilities.
  • Opti Logic OL2408: An 8-channel analog voltage input module that provides high-precision analog signal acquisition. It can be used with the Opti Logic OL4054 to monitor analog signals such as sensor outputs, enabling precise process control.
  • Opti Logic OL2104: A 4-channel relay output module offering switch output functionality. It can be used with the Opti Logic OL4054 to control actuators such as valves and motors, achieving equipment control and automation.

Installation and Maintenance

  • Installation: Ensure the installation environment is well-ventilated, free from conductive dust and corrosive gases, and within the specified temperature and humidity ranges. The Opti Logic OL4054 can be mounted on a DIN rail or panel. During installation, secure the device firmly and ensure proper grounding to enhance electromagnetic compatibility and operational reliability. When connecting power and communication cables, follow the wiring diagram and ensure connections are correct and secure.
  • Maintenance: Regularly inspect the device’s appearance and connections to ensure there is no damage or looseness. Clean the device surface with a dry cloth to remove dust and dirt. Check the status of indicator lights to monitor the device’s operating condition. Perform regular calibration of I/O modules to ensure measurement and control accuracy. If any abnormalities are detected during operation, promptly troubleshoot and resolve issues or contact the manufacturer for technical support.

Product Warranty

Xiamen Xiongba E-commerce Co., Ltd. Branch offers a one-year warranty for the Opti Logic OL4054, covering manufacturing defects and performance issues. During the warranty period, we provide free replacement services to ensure minimal disruption to production activities. Our global support network ensures customers worldwide receive timely technical assistance and consultation services. Our professional engineering team is dedicated to addressing your concerns and helping you maximize the value of the Opti Logic OL4054.